H603 Large Angle Tilt Sensor


CSA Approved Intrinsically Safe sensors for Hazardous DUST atmospheres
Available in any travel from 15° to 160°


The Positek H603 TIPS® (Tilt Inductive Position Sensor) incorporates electronics system EX06 which is CSA approved for use in potentially explosive gas/vapour and dust atmospheres.
The H603 is designed for industrial and scientific feedback applications and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas. The H603, like all Positek® sensors, is supplied with the output calibrated to the angle required by the customer, between 15 and 160 degrees and with full EMC protection built in. The sensor provides a linear output characteristic with angle of deflection. There is a machined registration mark to identify the calibrated mid point.


Overall performance, repeatability and stability are outstanding over a wide temperature range. Electrical connections to the sensor are made via an industrial standard 4-pin M12 connector, with limited rotational capability to facilitate cable routing.
The sensor has a rugged stainless steel body and mounting flange. The flange has two 4.5mm by 30 degree wide slots on a 48mm pitch to simplify mounting and position adjustment. Environmental sealing is to IP67.


Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier .  Approved galvanic isolation amplifiers (G005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.



Specification

Intrinsic Safety

 

CSA approval

CSA approved to; Class I, Zone 0
AEx ia IIC T4 (Ta = -40°C to +80°C)
AEx iaD IIIC T93°C(Ta = -40°C to +80°C)
Designates the sensor as belonging to; Class I, Zone 0:
suitable for all areas except mining, : can be used in areas
with continuous, long or frequent periods of exposure to
hazardous gas or dust
Gas:
Protection class ia IIC, denotes intrinsically safe for Zones
0, 1 & 2 and IIA, IIB and IIC explosive gases.
Temperature class T4: maximum sensor surface
temperature under fault conditions 135°C.
Dust:
T93°C: maximum sensor surface temperature under fault
conditions 93°C.
Ambient temperature range extended to -40°C to +80°C.

Galvanic Isolation Amplifier

It is imperative Positek® intrinsically safe sensors be used in
conjunction with a galvanic barrier to meet the requirements
of the product certification. The Positek G005 Galvanic
Isolation Amplifier is purpose made for Positek IS sensors
making it the perfect choice. Refer to the G005 datasheet for
product specification and output configuration options.

The Positek® G005 Galvanic Isolation Amplifier is available with 0.5 - 9.5V
or 4 - 20mA transmission output options or reverse outputs of 9.5 - 0.5
volts or 20 - 4 mA

Sensor Specification

 

Dimensions

 

Body Diameter

35mm

Body Length (to seal face)

44mm

 

For full mechanical details see drawing

Measurement range

Any angle from ±10° to ±80°

Independant Linearity / Hysterisis
(combined error)

<±0.25°

Temperature Coefficient

<±0.01%/°C Gain & <±0.01%FS/°C Offset

Output characteristics

Response Time

250mS @ 20°C typical

Damping Ratio

0.2 : 1 (0.6 nom. @ 25°C )

Resolution

Infinite

Noise

<0.02% FSO

 

 

Temperature Limits

 

Operating

-20 to + 80°C

Storage

-40 to + 125°C

EMC Performance

 

Susceptibility

EN 61000-6-2

Radiated

EN 61000-6-3

 

 

Vibration

IEC 68-2-6: 10g

Shock

IEC 68-2-29: 40 g

MTBF

350,000 hrs 40°C Gf

Sealing

IP67

 

 

Electrical Connections

Integral connector

Detailed Dimensions

Refer to drawings below.

Galvanic Isolation Amplifier

Click for pdf

Outline

Click for pdf
Request AutoCAD Drawing
Datasheet Click for pdf
Installation Sheet Click for pdf


Preferences

Positek offers a range of options for its standard sensors.
Each sensor is manufactured to suit each customer's preferences.
If your requirement is outside the options given below,
Positek can modify/ redesign a sensor to suit your specific requirement.
Standard options are available as below:

 

Measurement range:

Factory set to Any angle from ±7.5° to ±80° in increments of 1°
For example, if your application requires 90° measurement
then Positek will manufacture the sensor specifically for this angular range.
The sensor will measure 90° however will still rotate through 360°.






Click Here For Approved Galvanic Isolation Amplifier Options

 

 

 

Free Design Service

If you need a position sensor that is outside the scope of the above options to suit your installation requirement or specification, Positek will be happy to modify or create a new design to suit your needs


Contact Positek Technical Department - Click Here


 

Get Price


Back To Top

Home Page Quality | Products | Part Number Coding | Case Studies |

| Help Desk | Enquiries | Distributors | How to find us |

 

   


Company logo

 

Home

Products

Enquiries

How To Buy

Quality

Product Index

Support

ATEX logo

IECEx

iso 9001:2000 logo


  Positek Limited

L6 The Link   Andoversford Industrial Estate   Cheltenham   Glos GL54 4LB   UK
Tel: +44 (0) 1242820027   Fax: +44 (0)1242 820615   Email: Sales@Positek.com